Highlights
- 24x C13 and 3x C19 for high connector density in the server rack
- Phase measurement for precise energy monitoring
- 3 m supply cable with CEE 16A plug (blue)
- SNMP & web interface for remote monitoring
- 2x Gigabit Ethernet and TFT color display
BN ESSENTIAL Metered Rack PDU – 24x C13 with Energy Monitoring for Server Rack & Data Center
The Bachmann BN ESSENTIAL Metered PDU is a powerful solution for professional power distribution in server racks and data centers. With 24x C13 and 3x C19 outlets it offers a high outlet density for servers, switches and IT hardware. The integrated phase measurement enables precise monitoring of all relevant electrical parameters and provides maximum transparency in energy distribution.
Thanks to the 3 meter long supply cable with CEE 16A plug (blue), the PDU is flexible to use and quick to install. Vertical mounting saves valuable rack space and makes it the ideal solution for modern IT infrastructures.
Technical data & features for rack PDU and power distribution in the server rack
- Product: Bachmann BN ESSENTIAL Metered Rack PDU
- Measurement per phase
- Input: 16A / 230V / 3.6 kW
- Output: 24x C13 0° IEC appliance socket, 3x C19 90° IEC appliance socket
- Supply cable: 3.0 m / 2.5 mm²
- Plug: CEE 16A (blue)
- Measurement of current, voltage, reactive power, apparent power, active power, active energy, frequency and power factor
- Hot-swappable controller
- Integrated web server with web interface
- SNMP-capable
- 2x RJ45 (1 Gbit/s Ethernet)
- 1x USB-A port
- 2x interfaces for sensors
- 2.0" TFT color display
- Mounting orientation: vertical (0U)
- Color: aluminum
- Mounting dimension: 1,025.6 mm
- Length: 1,000.4 mm
- Width: 44 mm
- Depth: 58.6 mm
- Supply voltage: 230 V
- Rated current: 16 A
- Overvoltage category: CAT II
- With meter: Yes
- Switchable: No
- With display: Yes
- Temperature measurement integrated
- Includes mounting hardware
- RoHS compliant
- Country of origin: Romania
| Product sheet: | |
|---|---|
| Technical drawing: | |
| RoHS / REACH: | |
| Installation manual: | |
| Warning/safety instructions: | |
| Contains installation material: | + |
| Warranty: | 3 years |
| Manufacturer/Importer: | Bachmann GmbH, Ernsthaldenstr. 33, 70565 Stuttgart, info@bachmann.com |
| Einspeisung: | 16A |
| Größe PDU: | Vertikal, 40 HE |
| Messen: | pro Phase |
| Number of sockets: | 27 Outlets |
| Phasen: | 3-phasig |
| RCM-Differenzstrommessung: | Nein |
| Schalten: | Nein |
| Steckerart: | C13, C19 |
| Strommessung / Überwachung: | Ja, nur Display |
| color: | Black |
| USB-Charger: | USB A |
If warning and safety instructions are to be observed for a product, these can be found in the respective installation instructions or in a separate PDF, depending on the manufacturer. Available documents for the product can be found in the available PDF files (see above).
Download area - catalogs, flyers, warranty conditions, ...
0 of 0 reviews
Average rating of 0 out of 5 stars
Questions & Answers
-
What is the BN ESSENTIAL Metered Rack PDU?
The BN ESSENTIAL Metered Rack PDU is a rack PDU with 24x C13 outlets and 3x C19 outlets with energy monitoring for servers and data centers.
-
How many outlets does it have and what types are they?
It has 24x C13 outlets and 3x C19 outlets.
-
What is the input lead and plug?
It has a 3.0 m lead with a CEE 16A (blue) plug.
-
What parameters does it meter?
It meters current, voltage, reactive power, apparent power, real power, active energy, frequency and power factor.
-
Does it have a web server or network features?
Integrated web server with a web interface; SNMP capable; 2x RJ45 (1 Gbps Ethernet) and 1x USB-A port.
-
What is the mounting orientation?
Vertical mounting (0U).
-
What are its dimensions and appearance?
Dimensions: length 1000.4 mm, width 44 mm, depth 58.6 mm; colour aluminum.
-
What additional features does it have?
Two sensor interfaces, temperature measurement integrated, 2.0-inch TFT colour display, mounting hardware included, RoHS compliant, country of origin Romania.
Kunden kauften auch
Average rating of 0 out of 5 stars
Average rating of 0 out of 5 stars
Average rating of 0 out of 5 stars
Average rating of 0 out of 5 stars
Average rating of 0 out of 5 stars
FAQ - Häufig gestellte Fragen
Why is a metered rack PDU indispensable in the server rack?
The Bachmann BN ESSENTIAL Metered Rack PDU is a central component for reliable power distribution in modern server racks and data centers. In professional IT environments, a stable power supply is crucial to prevent outages and ensure operational safety. This PDU addresses exactly that: it combines high outlet density with precise energy monitoring, enabling efficient and transparent power distribution throughout the rack. With a total of 24x C13 and 3x C19 outlets, the PDU offers sufficient capacity for servers, storage systems, switches and other network components. Vertical mounting (0U) does not occupy valuable rack space, which is a major advantage in densely populated server cabinets.
What advantages does the integrated energy monitoring offer?
A decisive added value of this metered PDU is the integrated per-phase measurement. It enables a detailed analysis of all relevant electrical parameters such as current, voltage, active power, reactive power, apparent power, as well as energy consumption, frequency and power factor. These comprehensive measurement data give operators full transparency about the current load and energy efficiency of their IT infrastructure. Through this continuous monitoring, load peaks can be detected early and specifically balanced. This not only reduces the risk of overloads but also contributes to optimizing energy consumption. Especially in data centers where energy costs play a major role, this is an important factor for economical operation.
How is the rack PDU integrated into existing networks?
The BN ESSENTIAL Metered PDU is optimally designed for use in networked IT environments. Thanks to the integrated web server with an intuitive web interface, all measurement data can be conveniently accessed and evaluated via the browser. In addition, the SNMP function allows easy integration into existing monitoring and management systems commonly used in professional data centers. The two integrated Gigabit Ethernet ports (RJ45) ensure a stable and redundant network connection. This is complemented by a USB-A port as well as two interfaces for external sensors, for example for temperature monitoring. The integrated 2.0" TFT color display also provides quick local checks directly at the rack.
For which application areas is this Bachmann PDU suitable?
This Bachmann BN ESSENTIAL Metered - 16/3p Rack PDU with 24xC13, 3xC19 & Display (BM0024222) is ideal for use in data centers, server rooms, network cabinets and demanding IT environments. Wherever reliable power distribution with detailed monitoring is required, it plays to its strengths. Companies with growing IT infrastructures particularly benefit from the high outlet density and extensive monitoring functions. The combination of robust construction, a powerful CEE 16A feed and modern network integration makes this PDU a future-proof solution for professional applications. It helps administrators operate their systems efficiently, prevent outages and optimally control power distribution in the server rack.